(02) 4924 5400
mail@advitechgroup.com.au
(02) 4924 5400
Facebook
LinkedIn
    MENUMENU
    • Home
    • Services
            • STEM-Based Consulting
            • Engineering Consulting
            • Asset Integrity and Reliability
            • Environment
            • National Pollutant Inventory Reporting
            • Functional Safety and Risk
            • Project Delivery
            • Process Safety
            • Simulation and Modelling
            • Energy and Sustainability
            • Energy Efficiency
            • Resource Optimisation
            • Carbon Management
            • Smart Systems
            • Sensor Networks
            • Industrial Internet of Things (IIoT)
            • Communication Networks
            • Intercepta Smart Radar Camera
            • Advanced Manufacturing
            • Advanced Manufacturing
            • Integrated Noise Management
            • Noise Monitoring Data
            • AI Noise Mgmt
            • Data Intelligence
            • Noise Control Solutions
            • Operational Noise Control
            • Noise Mgmt Life Cycle
          • Contact Advitech about your

            Engineering Needs

            +61 2 4924 5400
          • Contact Advitech about your

            Environment Needs

            +61 2 4924 5400
          • Contact Advitech about your

            Project Delivery Needs

            +61 2 4924 5400
          • Contact Advitech about your

            Safety and Risk Management Needs

            +61 2 4924 5400
          • Contact Novecom about your

            Industrial Internet of Things (IIoT) Needs

            +61 2 4924 5460
          • Contact Advitech about your

            Resource Optimisation Needs

            +61 2 4924 5400
          • Contact Novecom about your

            Intercepta Smart Radar Camera Needs

            +61 2 4924 5460
          • Contact Acubis Technologies about your

            Wireless Networks Needs

            +61 1300 660 676
          • Contact Novecom about your

            Sensor Networks Needs

            +61 2 4924 5460
          • Contact Simulation Modelling Services about your

            Simulation and Modelling Needs

            +61 2 4926 1500
          • Contact Advitech about your

            Carbon Management Needs

            +61 2 4924 5400
          • Contact Advitech about your

            Energy Efficiency Needs

            +61 2 4924 5400
          • Contact Advitech about your

            Advanced Manufacturing Needs

            +61 2 4924 5400
          • Contact Novecom about your

            Noise Monitoring Data Needs

            +61 2 4924 5460
          • Contact Advitech about your

            AI Noise Mgmt Needs

            +61 2 4924 5400
          • Contact Advitech about your

            Data Intelligence Needs

            +61 2 4924 5400
          • Contact Hushpak Engineering about your

            Noise Control Solutions Needs

            +61 2 4964 4000
          • operational noise control

            Contact Advitech about your

            Operational Noise Control Needs

            +61 2 4924 5400
          • Contact Advitech about your

            Noise Mgmt Life Cycle Needs

            +61 2 4924 5400
    • Services
      • STEM-Based Consulting
        • Environment
        • National Pollutant Inventory Reporting
        • Functional Safety and Risk
        • Process Safety
        • Simulation and Modelling
      • Engineering Consulting
        • Project Delivery
      • Smart Systems
        • Sensor Networks
        • Industrial Internet of Things (IIoT)
        • Communication Networks
        • Intercepta Smart Radar Camera
      • Integrated Noise Management
        • Noise Monitoring Data
        • AI Noise Mgmt
        • Data Intelligence
        • Noise Control Solutions
        • Operational Noise Control
        • Noise Mgmt Life Cycle
      • Energy and Sustainability
        • Energy Efficiency
        • Resource Optimisation
        • Carbon Management
      • Advanced Manufacturing
    • Projects
    • Sectors
      • Mining
      • Coal Preparation and Handling
      • Agriculture
      • Defence
      • Manufacturing
      • Infrastructure
      • Performance Venues
      • Government Agencies
      • Warehouse and Distribution
    • About
      • The Advitech Group
      • Management Team
      • History
      • Working Here
    • Companies
      • Advitech
      • Novecom
      • Hushpak
      • Acubis
      • SMS
    • News
    • Contact

News

Home Case Studies Controlling Workplace Noise at a Coal Preparation Plant

Controlling Workplace Noise at a Coal Preparation Plant

October 31, 2018Advitech Case Studies, Environment, Integrated Noise Management, MiningSarah King

Client

A Hunter Valley coal mine operator

The project was undertaken at the coal preparation plant (CPP) at a Hunter Valley mine site.

Challenge

Operators of the CPP were concerned about the acoustic impact of a vacuum pump on the surrounding work environment, and the noise exposure of workers in the area. Site personnel had reported high levels of noise emanating from the vacuum pump since recent modifications.

Recognising Advitech Environmental’s experience in vibration, acoustics and engineering, we were engaged to undertake an acoustic assessment at the site and recommend vibro-acoustic engineering solutions to reduce machine emissions to an acceptable level.

Solution

The project involved an initial acoustic assessment to understand the noise problem, followed by the design of a new exhaust system to attenuate the noise emanating from the vacuum pump.

Acoustic assessment

Advitech Environmental’s acoustics specialists undertook an acoustic assessment in accordance with the WHS Regulation 2011, Chapter 4 Hazardous Work, Part 4.1 Noise.

The client provided detailed information relating to the operation of equipment within the CPP. The assessment looked at the relationship between vacuum pump operating speeds and acoustic frequencies, allowing for narrow band airborne noise contributions to be matched to particular machines.

Audible noise sources detected during the assessment included a discrete tone emanating from the vacuum pump and the continual hum of the CPP operations. During the monitoring period, the pump noise displayed both tonal and impulsive acoustic modes of operation.

Advitech Environmental recommended that an engineered noise control solution was required to reduce the acoustic impact to an acceptable level. This would involve the design of a custom muffler to be installed within the exhaust pipe system.

Design of a new exhaust system

Our acoustic specialists teamed up with Advitech’s structural engineers to design the replacement exhaust system. Advitech’s engineering team was ideally placed to complete the design, as they had the knowledge and insight necessary to consider all aspects of the project including the acoustic properties of both air borne and structural borne noise emissions.

The existing polyethylene exhaust pipe was modelled in the Strand7 finite element analysis software, based on the manufacturers specifications. The Youngs modulus of the material was noted to change with temperature, so a conservative value was adopted.

The Strand7 natural frequency solver was used, finding several vibrational modes present in the exhaust around the blade pass frequency for the vacuum pump fan. These vibrational modes were predominantly associated with the development of standing waves radially along the exhaust pipe. The vibrational modes could be excited by vibrations from unbalanced loads within the fan or pressure fluctuations (noise) from the pump. The resonance of the exhaust pipe would result in displacement and pressure variations of the air surrounding the exhaust pipe. The pressure variations emanating from the exhaust pipe are effectively another noise source on top of what was already emanating from the vacuum pump.

A second model was prepared with similar overall geometry, but using steel pipe instead of polyethylene. Natural frequency analysis on the steel exhaust found the frequencies of the vibrational modes were much higher thanks to the increased stiffness of the material. No vibrational modes were identified near to the pump fan blade pass frequency, limiting any potential resonance. Additionally, the vibrational mode nearest to the fan blade pass frequency was associated with a rotational mode within the pipe. Excitation of this rotational mode would not result in any additional air movement and pressure fluctuations (noise) emanating from the exhaust.

As a result of the analysis, Advitech recommended replacement of the polyethylene pipe with a steel pipe. From a vibro-acoustic perspective, the Advitech team was able to model and engineer a new exhaust system (comprising a retro-fitted muffler unit and tuned steel pipe exhaust) that could achieve a satisfactory reduction in noise emissions – for a significantly reduced cost compared to other noise mitigation options.

Outcome

The new exhaust system was manufactured and installed according to Advitech’s design. A noise survey conducted after installation demonstrated a reduction in noise emissions and occupational exposure of approximately 8dB(A). Prior to installation, the vacuum pump produced noise in the range 93 to 97 dB(A). After noise control treatment, noise emissions decreased to 85 to 89 dB(A).

By choosing The Advitech Group – built on the foundations of STEM&M – the mine operator benefited from the combined forces of our acoustics and structural engineering specialists, engaging just one organisation to achieve a complete solution from assessment through to the delivery of a successful result.

More info

For more information on this case study, or to enquire about a similar project please contact:

Clayton Sparke | Environment Specialist – Acoustics, Advitech Environmental
clayton.sparke@advitech.com.au
+61 2 4924 5400

Previous Post Radio Frequency RF Propagation Survey identifies dead spots Next Post Biodiversity Assessment (BDAR) for NSW Inland Rail Project

Want to know more?

Sign up for the latest news from The Advitech Group

Sign up

Contact Info

The Advitech Group Head Office

Address 7 Riverside Drive, Mayfield West Newcastle, NSW 2304, Australia

Email mail@advitechgroup.com.au

Phone (02) 4924 5400

Request a callback

Services

  • STEM-Based Consulting
  • Smart Systems
  • Integrated Noise Management
  • Energy and Sustainability
  • Advanced Manufacturing

Sectors

  • Mining
  • Coal Preparation and Handling
  • Agriculture
  • Defence
  • Manufacturing
  • Infrastructure
  • Government Agencies
  • Policies
  • Privacy
Email
Facebook
LinkedIn

©  2018 The Advitech Group – Login